Phase 6: ACTIVE Coast Adjustment Plan

Status: IMPLEMENTED (Phase 6j - November 26, 2025) Date: 2025-11-26 Problem: Current INACTIVE-based corrections have limited headroom at high motor duty Solution: Asymmetric correction - catch-up in ACTIVE coast, slow-down in INACTIVE

Implementation Complete: Phase 6j implemented on November 26, 2025. - Catch-up (negative drift): Shortens ACTIVE coast period - Slow-down (positive drift): Extends INACTIVE period (unchanged) - PD damping applied to both correction types - Headroom at high duty cycles vastly improved


Current Approach (INACTIVE Adjustment)

Timeline at 1Hz (1000ms period, 500ms half-period):

SERVER: |===== ACTIVE =====|----- INACTIVE -----|===== ACTIVE =====|
        0                 500                  1000               1500

CLIENT: |----- INACTIVE ----|===== ACTIVE =====|----- INACTIVE ----|
        0                  500                 1000               1500
                    Correction applied here
                    (adjust INACTIVE duration)

The Problem: - To catch up: CLIENT shortens INACTIVE (starts ACTIVE earlier) - Floor constraint: Can't start ACTIVE while SERVER is still in ACTIVE - Floor = motor_on + coast ≈ 250-450ms at high duty - At high duty: floor ≈ INACTIVE → near-zero headroom


Proposed Approach (ACTIVE Coast Adjustment)

Key Insight: Corrections should happen at END of ACTIVE, not START of ACTIVE.

Catch-up scenario (CLIENT is behind):

Current (risky):
  CLIENT shortens INACTIVE → starts ACTIVE earlier → might overlap SERVER's ACTIVE

Proposed (safe):
  CLIENT shortens ACTIVE coast → ends ACTIVE earlier → enters INACTIVE sooner
  → next cycle starts sooner → caught up!

  No risk of overlap: we're ending our turn early, not starting early.

Asymmetric Correction Strategy

Scenario Correction Where Applied Risk Headroom
CLIENT behind (catch up) Negative Shorten ACTIVE coast None (ending early) ~400ms
CLIENT ahead (slow down) Positive Lengthen INACTIVE None (waiting longer) Unlimited

Why asymmetric? - Shortening ACTIVE = ending our motor early = safe - Lengthening ACTIVE = running motor longer = risks overlap with SERVER's next ACTIVE - Shortening INACTIVE = starting motor early = risks overlap with SERVER's ACTIVE (current floor problem) - Lengthening INACTIVE = waiting longer before motor = safe


Timing Structure (Clarified Terminology)

One full period (e.g., 1000ms at 1Hz):
├── ACTIVE (this device's half-period, ~500ms)
│   ├── MOTOR_DRIVE: PWM driving motor (motor_on_ms)
│   ├── COAST: Motor freewheeling (coast_ms) ← CATCH-UP ADJUSTMENT HERE
│   └── BEMF_SAMPLE: Optional back-EMF reading
└── INACTIVE (other device's half-period, ~500ms) ← SLOW-DOWN ADJUSTMENT HERE
    └── Motor completely off (sacred promise)

Motor Duty Percentage

Motor Duty MOTOR_DRIVE COAST Total ACTIVE INACTIVE
50% 250ms 0ms 250ms 500ms + 250ms gap
75% 375ms 0ms 375ms 500ms + 125ms gap
90% 450ms 0ms 450ms 500ms + 50ms gap
100% 500ms 0ms 500ms 500ms (seamless)

Wait, this doesn't match our current structure. Let me reconsider...

Current structure (I think): - ACTIVE phase = motor_on + coast + BEMF, duration determined by duty% - INACTIVE phase = remaining time in half-period - At 100% duty: ACTIVE fills entire half-period, INACTIVE = other device's half-period

Clarified structure:

At 1Hz, 100% motor duty:
  Half-period = 500ms

  ACTIVE = 500ms (motor driving, possibly with small coast for BEMF)
  INACTIVE = 500ms (motor off, other device's turn)

  Total cycle = 1000ms


State Machine Changes

Current States

CHECK_MESSAGES → FORWARD_ACTIVE → BEMF → COAST_SETTLE → INACTIVE → back to CHECK
                       ↓                                    ↓
                  (motor on)                        (correction here)

Proposed States

CHECK_MESSAGES → MOTOR_DRIVE → COAST_ADJUST → INACTIVE → back to CHECK
                      ↓              ↓             ↓
                 (motor on)   (catch-up adj)  (slow-down adj)

Changes: 1. COAST_ADJUST state: Variable duration based on catch-up correction 2. INACTIVE state: Variable duration based on slow-down correction (or fixed at half-period) 3. Correction logic split between two states based on sign

Pseudocode

// In MOTOR_DRIVE state (end of motor_on period):
// Calculate where we should be vs where we are
int32_t drift_ms = calculate_drift_from_server_epoch();

if (drift_ms < 0) {
    // CLIENT is behind, need to catch up
    // Shorten ACTIVE coast to end cycle sooner
    int32_t catch_up_ms = -drift_ms;  // positive value

    // Clamp to available coast time
    int32_t max_coast_reduction = coast_ms - MIN_COAST_MS;  // e.g., 50ms minimum
    if (catch_up_ms > max_coast_reduction) {
        // Need more than coast allows - borrow from motor_on next cycle?
        // Or request duty reduction from SERVER?
        catch_up_ms = max_coast_reduction;
        // Flag: correction_limited = true
    }

    actual_coast_ms = coast_ms - catch_up_ms;
    inactive_ms = HALF_PERIOD_MS;  // Fixed, keep the promise

} else if (drift_ms > 0) {
    // CLIENT is ahead, need to slow down
    // Lengthen INACTIVE to delay next cycle
    actual_coast_ms = coast_ms;  // Nominal
    inactive_ms = HALF_PERIOD_MS + drift_ms;  // Extended wait

} else {
    // Perfectly aligned
    actual_coast_ms = coast_ms;
    inactive_ms = HALF_PERIOD_MS;
}

// Transition to COAST_ADJUST state, wait actual_coast_ms
// Then transition to INACTIVE state, wait inactive_ms

Headroom Analysis

Current Approach (INACTIVE Adjustment)

At 2Hz (250ms half-period), 90% motor duty: - ACTIVE = 225ms (motor_on=200ms, coast=25ms) - INACTIVE = 250ms - Floor = motor_on + coast = 225ms - Catch-up headroom = 250ms - 225ms = 25ms ← Very limited!

Proposed Approach (ACTIVE Coast Adjustment)

Same scenario: - ACTIVE = 225ms (motor_on=200ms, coast=25ms) - MIN_COAST = 10ms (for BEMF if needed) - Catch-up headroom from coast = 25ms - 10ms = 15ms

That's still limited! But we can also borrow from motor_on: - MIN_MOTOR_ON = 50ms (motor startup minimum) - Additional headroom from motor_on = 200ms - 50ms = 150ms - Total catch-up headroom = 15ms + 150ms = 165ms ← Much better!

The 100% Motor Duty Case

At 100% duty, coast_ms = 0. All headroom comes from motor_on: - motor_on = 250ms (entire half-period at 2Hz) - MIN_MOTOR_ON = 50ms - Catch-up headroom = 250ms - 50ms = 200ms

This is 8× better than current approach at high duty!


Do We Need CLIENT → SERVER Feedback?

When Would CLIENT Be Unable to Keep Up?

With ACTIVE adjustment headroom of ~200ms at 2Hz: - Normal drift: ~30μs per 90 minutes (measured) - Maximum correction per cycle: 200ms - CLIENT would need drift > 200ms per cycle to be unable to keep up - That's 80% phase error per cycle = catastrophic clock failure

Conclusion: Under normal operation, CLIENT should ALWAYS be able to keep up.

Edge Cases Where Feedback Might Help

  1. Repeated motor_on borrowing: If CLIENT consistently borrows from motor_on (reducing therapeutic intensity), it could notify SERVER.

  2. Hardware degradation: If Bluetooth interference or clock issues cause sustained drift, feedback could trigger investigation.

  3. User preference: Some users might prefer "perfect sync" over "consistent motor intensity" - feedback enables this choice.

Proposed Feedback (Optional Enhancement)

// If CLIENT borrows from motor_on more than 3 consecutive cycles:
coordination_message_t feedback = {
    .type = SYNC_MSG_DUTY_REDUCTION_REQUEST,
    .payload.duty_reduction_pct = 5  // Request 5% reduction
};
ble_send_coordination_message(&feedback);

// SERVER receives and both devices reduce duty
// Creates more coast headroom for corrections
// Can be restored after sync stabilizes

Recommendation: Implement feedback as Phase 6b enhancement, not required for initial refactor.


Implementation Plan

Phase 6a: ACTIVE Coast Adjustment (Core Refactor)

  1. Modify motor_task.c state machine:
  2. Add COAST_ADJUST state (or rename existing COAST_SETTLE)
  3. Move catch-up correction from INACTIVE to COAST_ADJUST
  4. Keep slow-down correction in INACTIVE

  5. Update drift calculation:

  6. Calculate at end of MOTOR_DRIVE (before coast)
  7. Determine correction sign and magnitude
  8. Route to appropriate adjustment (coast vs inactive)

  9. Add motor_on borrowing:

  10. If coast headroom insufficient, borrow from motor_on
  11. Track borrowed amount for logging/diagnostics
  12. Clamp to MIN_MOTOR_ON (50ms suggested)

  13. Update logging:

  14. Log correction type (coast vs inactive vs motor_on borrow)
  15. Track headroom usage for tuning

Phase 6b: CLIENT Feedback (Optional Enhancement)

  1. Add SYNC_MSG_DUTY_REDUCTION_REQUEST message type
  2. CLIENT tracks consecutive motor_on borrows
  3. SERVER handles duty reduction request
  4. Both devices coordinate duty change
  5. Auto-restore duty after sync stabilizes

Testing Strategy

Unit Tests (If Applicable)

  • Drift calculation with known inputs
  • Correction routing (coast vs inactive)
  • Motor_on borrowing threshold

Hardware Tests

  1. Basic antiphase at various duty cycles:
  2. 50%, 75%, 90%, 100% motor duty
  3. 0.5Hz, 1Hz, 2Hz frequencies
  4. Verify no perceptible gap/overlap

  5. Correction responsiveness:

  6. Introduce artificial drift (delay one device's boot)
  7. Measure cycles to achieve antiphase
  8. Target: < 3 cycles (was 10+ cycles)

  9. Motor_on borrowing perception:

  10. At 100% duty, cause correction requiring motor_on borrow
  11. User perception test: is 450ms vs 500ms motor_on noticeable?

  12. Long-duration stability:

  13. 20-minute session at high duty
  14. Monitor for accumulated drift
  15. Verify no sync degradation

Open Questions

  1. MIN_MOTOR_ON value: 50ms suggested. Too conservative? Motor startup time is ~10-20ms.

  2. MIN_COAST value: 10ms suggested for BEMF. Can we go to 0ms if BEMF not needed?

  3. INACTIVE adjustment limit: Should we cap slow-down correction to prevent one device waiting too long?

  4. PD controller integration: Does the damped correction approach still apply, or does asymmetric adjustment change things?

  5. SERVER behavior: Should SERVER ever adjust, or always be the reference? (Current: SERVER is reference.)


Summary

Aspect Current Proposed
Catch-up correction Shorten INACTIVE Shorten ACTIVE coast
Slow-down correction Lengthen INACTIVE Lengthen INACTIVE (same)
Floor constraint motor_on + coast (~250ms) MIN_MOTOR_ON (~50ms)
Headroom at 90% duty, 2Hz ~25ms ~165ms
Headroom at 100% duty ~0ms (broken) ~200ms (works!)
CLIENT feedback needed N/A Optional enhancement
Complexity Medium Medium (different, not harder)

Bottom Line: This refactor should eliminate the sync problems at high duty cycles while maintaining clinical compatibility with existing EMDR devices that expect seamless L↔R alternation.